AC Leaking Water? Why Your Air Conditioner Drips Inside — and What to Do
Water dripping from around your indoor AC unit, a stain spreading on the ceiling below the attic air handler, or a puddle by the furnace closet — an air conditioner "leaking water" alarms people, and fair enough: the water can do more damage than the underlying failure costs to fix. The good news is that the causes are few, and the first move is always the same.
First: Turn the Cooling Off
Every minute the AC runs, it pulls more moisture out of the air and makes more water. Switch the thermostat from COOL to OFF (leaving FAN on is fine), put a towel or pan under the drip, and the situation stops getting worse. Now it's a repair, not an emergency.
Cause #1: A Clogged Condensate Drain
The overwhelming favorite. Your AC's evaporator coil condenses gallons of water on a humid day, and it all leaves through a modest PVC drain line. In Orange County's warm attics that line grows algae, and by late summer it clogs. Water backs up into the drain pan, overfills it, and finds its way into your ceiling or floor. If your system has a float switch, it cuts the AC off first — which is why a clogged drain sometimes looks like a dead AC rather than a leak.
DIY that works: find the drain stub outside (a small PVC pipe near the outdoor unit or foundation), seal a wet/dry vacuum to it, and run it for a minute or two. If a slug of algae comes out and water follows, you've likely fixed it. What we don't recommend: forcing pressurized air or water from the outside inward — that can drive the clog deeper or pop a glued fitting hidden in a wall.
Cause #2: A Rusted or Cracked Drain Pan
Under the evaporator coil sits a drain pan; many systems have a secondary pan under the whole air handler in the attic. Metal pans rust through after 15–20 years, plastic ones crack. The symptom is a leak that continues even though the drain line is clear. Pans are replaceable — this is a normal repair, not a death sentence for the system.
Cause #3: A Frozen Coil, Melting
If the evaporator coil ices over — from a clogged filter, weak blower, or low refrigerant — the ice eventually melts faster than the drain can carry it away, and overflows the pan. The telltale: the leak appears right after the system shuts off, or you've noticed weak, warm airflow beforehand. Ice is its own problem with its own causes — see why an AC freezes up.
Cause #4: A Disconnected or Badly Sloped Drain Line
Sometimes the fitting at the pan simply comes loose, or the line was run with a sag where sludge settles and blocks flow. Common after attic work, pest-control visits, or any job where someone was crawling near the air handler.
Cause #5: A Failed Condensate Pump
Systems in garages, basements, and some closets can't drain by gravity, so a small pump pushes the water out. When the pump or its float sticks, the reservoir overflows quietly. If you can find the little box with tubes near your air handler, check whether it's full to the brim.
When to Call
Call us at (310) 600-8152 if the vacuum trick doesn't clear it, if the leak returns within days, if you see rust or standing water in the pan, or if the leak comes with ice or weak cooling — that points at airflow or refrigerant, which is AC repair territory. A cleared drain, flushed line, and tested float switch are also part of every AC maintenance visit — the cheapest way to never meet this problem in August.